Flash Points

Cleveland Open Cup Flash Point

Cleveland Open Cup Flash Point

  • Conforms to ASTM D92 and related specifications
  • For flash points above 79°C (175°F)

Determines flash and fire points by the Cleveland Open- Cup method. Consists of test flame applicator, brass test cup, thermometer support, heating plate and electric heater. Applicator is precisely aligned per specifications and pivots for test flame application at specified temperature intervals. Hinged thermometer support raises to facilitate placement and removal of test cup. Adjust flame size using built-in needle valve and comparison bead.

Equipped with a 1000W nickel-chromium heater with stepless variable heat control for accurate repeat setting of temperature rate of rise per specifications.

Tag Closed Cup Flash Point

Tag Closed Cup Flash Point

  • Conforms to ASTM D56 and related specifications

  • Gas or Electric Heating

Determines flash points of liquid products by the Tag Closed Cup method. Features stepless variable heat control with reference dial for accurate repeat setting of temperature rate of rise per specifications. Also available with gas burner instead of electric heater. Precision machined cover mechanism simultaneously opens slide shutter and applies test flame to sample at the turn of a knob. Includes liquid bath with constant level overflow, brass test cup, plated brass thermometer ferrules and test flame reference bead. Bath and cover mechanism are constructed of plated brass. Heater is enclosed in a cast aluminum base assembly.

Automatic PM D93 Flash Point Tester

Automatic PM D93 Flash Point Tester

For flash point determination of biodiesel, distillate fuels, new lubricating oils, residual fuel oils, cutback residual, used lubricating oils, mixtures of petroleum liquids with solids, petroleum liquids that tend to form a surface film during testing.

  • Conforms to ASTM D93 and related specifications
  • Flash Point Detection by Thermocouple and Ionization Ring
  • Electric or Gas ignition: Software selectable, User Friendly Manual Switching
  • Flash Point operation range between Ambient and 405°C
  • Integrated Dual Fan System directly cools test cup and surrounding environment
  •  8.4” LCD Touch Screen Interface makes for easy viewing and navigation
  • Automatic Barometric Pressure Correction
  • Fire Suppression System floods instrument with inert gas in the event of a fire
Manual PMCC Flash Point Tester

Manual PMCC Flash Point Tester

For flash point determinations of fuels, lubricating oils, liquids containing suspended solids and liquids that tend to form a surface film during testing.

Analyze Sulfur with Unparalleled Precision

  • Conforms to ASTM D93 and related specifications
  • Choice of electric or gas heating

Determines flash points of a wide range of products by a closed cup method with two option speed stirring of the sample. Extensively used in shipping and safety regulations for detection of contamination by volatile and flammable materials in fuel oils and lubricating oils, and for characterization of hazardous waste samples. Smooth operating cover mechanism slides shutter open and applies test flame at the turn of a knob. Cover fits over brass test cup and includes pilot flame, test flame reference bead, built-in stirrer and plated brass thermometer ferrule.

For Product and Sales Information Contact Us Today

sales@choiceanalytical.com or 832-271-7448