Call Today! (832) 271-7448

Conductivity

EMCEE Model 1152
Digital Conductivity Meter

ASTM Standard Test Method D 2624

  • Continuous standard electrical conductivity range from 0 to 1999 in increments of 1 picosiemen per meter (pS/m)
  • Available in other standard and non-standard conductivity ranges
  • Large digital, liquid crystal display
  • Reliable advanced integrated circuit design technology
  • Self check calibration with field adjustment capability
    Automatic over range and low battery indication
  • Capable of storage tank and tanker truck measurement with the use of a short cable or cable reel kit
  • Powered by 3 readily available alkaline batteries
  • Electronics housed in a rugged cast aluminum case coated with solvent resistant paint equipped
    with a detachable stainless steel probe
  • Approved intrinsically safe design for use in hazardous environments by Underwriters Laboratories (UL), Canadian Standards Association (CSA), and LCIE

Emcee Model 1153 Digital Conductivity Meter

ASTM Standard Test Method D 2624

  • Continuous standard electrical conductivity range from 0 to 2,000 picosiemens per meter (pS/m)
  • Available in other conductivity ranges (from2000 – 2MPs/m)
  • LED illuminates during automatic test cycle (3 seconds)
  • Temperature measured and displayed in Celsius and Fahrenheit
  • Data stored (non volatile) until next test cycle is performed
  • Hermetically sealed
  • Text presentation of operational status
  • Automatic over range and low battery indications
  • Single pushbutton operation
  • Digital, liquid crystal display
  • Powered by 3 standard lithium cells
  • Approved intrinsically safe design for use in hazardous environments by Underwriters Laboratories (UL) U.S., (UL) Canada and LCIE (Europe)

Emcee Model 1154 Precision Conductivity Meter

ASTM Standard Test Method D 4308

  • Four standard ranges provide high resolution and accurate direct measurement of electrical conductivity of fluids from.01 to 20,000
    picosiemens per meter (pS/m)
  • Capable of being modified to provide higher conductivity ranges
  • Optional capability to measure sample temperature
  • Mechanical design of the Conductivity (KSLA) Cell allows accurate self measuring of the test sample volume (100 mL)
  • Electronic circuitry automatically samples and holds the reading
  • Large five digit liquid crystal display
  • Internal self check calibration of all electronic circuits
  • Ease of disassembly and cleaning of the Conductivity Cell
  • Completely self contained powered by 6 standard 9 volt batteries monitored by a low battery indicator

For Product and Sales Information Contact Us Today

sales@choiceanalytical.com or 832-271-7448