EMCEE Model 1152
Digital Conductivity Meter
ASTM Standard Test Method D 2624
- Continuous standard electrical conductivity range from 0 to 1999 in increments of 1 picosiemen per meter (pS/m)
- Available in other standard and non-standard conductivity ranges
- Large digital, liquid crystal display
- Reliable advanced integrated circuit design technology
- Self check calibration with field adjustment capability
Automatic over range and low battery indication - Capable of storage tank and tanker truck measurement with the use of a short cable or cable reel kit
- Powered by 3 readily available alkaline batteries
- Electronics housed in a rugged cast aluminum case coated with solvent resistant paint equipped
with a detachable stainless steel probe - Approved intrinsically safe design for use in hazardous environments by Underwriters Laboratories (UL), Canadian Standards Association (CSA), and LCIE
Emcee Model 1153 Digital Conductivity Meter
ASTM Standard Test Method D 2624
- Continuous standard electrical conductivity range from 0 to 2,000 picosiemens per meter (pS/m)
- Available in other conductivity ranges (from2000 – 2MPs/m)
- LED illuminates during automatic test cycle (3 seconds)
- Temperature measured and displayed in Celsius and Fahrenheit
- Data stored (non volatile) until next test cycle is performed
- Hermetically sealed
- Text presentation of operational status
- Automatic over range and low battery indications
- Single pushbutton operation
- Digital, liquid crystal display
- Powered by 3 standard lithium cells
- Approved intrinsically safe design for use in hazardous environments by Underwriters Laboratories (UL) U.S., (UL) Canada and LCIE (Europe)


Emcee Model 1154 Precision Conductivity Meter
ASTM Standard Test Method D 4308
- Four standard ranges provide high resolution and accurate direct measurement of electrical conductivity of fluids from.01 to 20,000
picosiemens per meter (pS/m) - Capable of being modified to provide higher conductivity ranges
- Optional capability to measure sample temperature
- Mechanical design of the Conductivity (KSLA) Cell allows accurate self measuring of the test sample volume (100 mL)
- Electronic circuitry automatically samples and holds the reading
- Large five digit liquid crystal display
- Internal self check calibration of all electronic circuits
- Ease of disassembly and cleaning of the Conductivity Cell
- Completely self contained powered by 6 standard 9 volt batteries monitored by a low battery indicator